Generella plastprodukter

Plastprodukter för laboratoriearbete inom hantering, förvaring och analys av prover. Sortimentet omfattar bland annat rack, plaströr, plattor, filter, sprutfilter, vågskepp och labbpennor, samt övriga plastartiklar. Ett brett urval av format, material och funktioner gör det möjligt att täcka både standardiserade laboratorieprocesser och mer specifika behov inom forskning, diagnostik och industri.

  • Sartorius

    Minisart NY25 0.45µm Syringe Filters

    Minisart® NY with hydrophilic polyamide (nylon) is optimized for aqueous liquids and solvents with a pH of 3 - 14. Type 17846 with a pore size of 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version Q is a non-sterile bulk pack. Units can be sterilized by autoclaving or EO.
    17846----------Q
  • Sartorius

    Minisart NY25 GF+0.45µm Syringe Filter

    Minisart® NY Plus with glass fibre prefilter and hydrophilic polyamide (nylon) is optimized for aqueous liquids and solvents with a pH of 3 - 14. Type 1784C with a pore size of 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    1784C----------K
  • Sartorius

    Minisart PES 0.2µm Sterile, Syringe Filter

    Minisart® High Flow with polyethersulfone (PES) is optimal for highest flow rates and a pH of 3 - 12. Type 16532 with a pore size of 0.22 µm can be used for sterile filtration and has a male luer lock outlet. Version GUK is sterilized by gamma irradiation, verison K with EO.
    16532----------K | 16532--------GUK
  • Sartorius

    Minisart PES 0.45µm Sterile, Syringe Filters

    Minisart® High Flow with polyethersulfone (PES) is optimal for highest flow rates and a pH of 3 - 12. Type 16537 with a pore size of 0.45 µm can be used for clarification and has a male luer lock outlet. Version K is individually packed and sterilized by ethylene oxide (EO).
    16537----------K
  • Sartorius

    Minisart PES 0.45µm, G-sterile, Syringe Filter

    Minisart® High Flow with polyethersulfone (PES) is optimal for highest flow rates and a pH of 3 - 12. Type 16533 with a pore size of 0.45 µm can be used for clarification and has a male luer slip outlet. Version GUK is individually packed and sterilized by gamma irradiation.
    16533--------GUK
  • Sartorius

    Minisart RC15 0.2µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17761 with a pore size of 0.2 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17761----------Q
  • Sartorius

    Minisart RC25 0.2µm Sterile syringe filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17764ACK with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet and version ACK is individually packed and sterilized by ethylene oxide (EO).
    17764--------ACK
  • Sartorius

    Minisart RC25 0.45µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17765 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version R is a non-sterile bulk pack. Units can be sterilized by autoclaving or EO.
    17765----------K
  • Sartorius

    Minisart SRP15 0.2 µm Sterile Syringe Filter

    Minisart® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17573 with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet and version ACK is individually packed and sterilized by ethylene oxide (EO).
    17573--------ACK
  • Sartorius

    Minisart SRP25 0.45µm Syringe Filter

    Suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17576 pore size 0.45 µm can be used for sample preparation. It has a male luer slip outlet. Version K is a non-sterile pack. Units can be sterilized by autoclaving or EO.
    17576----------Q | 17576----------K
  • Sartorius

    Minisart SRP25 syringe filters

    Minisart® SRP with chemically inert hydrophobic PTFE is suitable for venting as well as harsh solvents with a pH of 1 - 14. Type 17575 with a pore size of 0.2 µm can be used for sample preparation and sterile filtration. It has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17575----------Q | 17575----------K
  • Sartorius

    MinisartCA_0,45µm_28mm_nsterile_500; (IVD)

    Provides fast and reliable filtration of small to medium volumes, complete with ready-to-connect filter units. Sartorius Minisart™ NML Syringe Filters, Nonsterile eliminate time consuming preparatory work, such as changing out the filter and cleaning the filtration system.
    17598----------Q
  • Sartorius

    MinisartGF_0,45µm_28 mm_sterile

    Minisart® NML Plus with glass fibre prefilter and surfactant-free cellulose acetate (SFCA) is optimized for particle-laden aqueous solutions or oils for a higher total throughput. Type 17829 with a pore size of 0.45 µm can be used for clarification and has a male luer lock outlet.
    17829----------K
  • Sartorius

    MinisartRC15 0.45µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17762 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17762----------K
  • Sartorius

    MinisartRC4 0.2µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17821 with a pore size of 0.2 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17821----------K
  • Sartorius

    MinisartRC4 0.45µm Syringe Filter

    Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17822 with a pore size of 0.45 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
    17822----------K
  • HEATHROW SCIENTIFIC

    OneRack Half-size Rack (POM)

    Made of Delrin® fiberglass-reinforced polyoxymethylene (POM) molded in a single, continuous piece so no assembly required and there are no detachable pieces.
    HS27501A | HS27501B | HS27502A | HS27502B | HS27501C | HS27504C | HS27505A | HS27505B | HS27505C | HS120398 | HS120399 | HS27502C | HS27503C | HS27504A | HS27514A | HS27503A | HS27503B
  • HEATHROW SCIENTIFIC

    OneRack PP Full-Size

    Tough and more highly resistant to acids, bases, solvents and heat. OneRack® durable racks are molded in a single, continuous piece so no assembly required and there are no detachable pieces. Made from Polypropylene
    HS27551A | HS27552B | HS27552A | HS27552C
  • HEATHROW SCIENTIFIC

    POP-UP Tube Rack

    Collapse for compact storage and “pop-up” for quick use. Made from polypropylene.
    HS24318 | HS24319 | HS24320B | HS24320P